Description:

For natural gas transmission pipelines, the risk of a low-probability but high-consequence failure event, such as a large, ignited gas release (rupture), poses significant challenges. However, with effective emergency response planning, operators and first responders can mitigate potential impacts. One key action required from the operator is the rapid closure of isolation valves to shut down the ruptured pipeline segment. Isolation valves can be manually operated (MOV), remotely controlled (RCV), or automatic shut-off valves (ASV), with RCVs and ASVs—collectively known as rupture mitigation valves (RMV)—offering faster response times.

While rapid pipeline isolation alone may not significantly reduce initial consequences, when combined with coordinated emergency response measures, such as firefighting secondary building fires, it can help reduce damage severity. This paper introduces an approach to evaluating emergency response effectiveness by integrating rapid valve closure with firefighter intervention following a hypothetical rupture.

Date Published: October 22, 2024